Water Quality Monitoring: Temperature Change

Temperature Change

Test Equipment

Procedure

  1. At the test site where the other water quality tests are being performed and close to the time that the dissolved oxygen sample is being taken, lower the thermometer approximately ten centimeters below the water surface.
  2. Keep the thermometer in the water until a constant reading is attained. Other meters remain for three minutes and this is recommended for the thermometer as well.
  3. Remove the thermometer from the water and read the temperature as quickly and as accurately as possible. Read to the nearest 0.1 degree. Do not shake the thermometer, since it will cause the reading to change more quickly. Record the water temperature on the field data sheet.
  4. Proceed to the upstream location where Adams meets the creek. The sidewalk on the north side of the creek will lead you there. Use the string to dangle the thermometer over the fence and into the water for three minutes, read, and record the upstream temperature as before. Try to find a place within reach where the physical conditions most resemble those at the test site.
  5. Proceed to the downstream location where Pierce crosses over the creek. The path on the south side of the creek will lead you there. Use the string to dangle the thermometer over the side of the bridge and into the water for three minutes, read, and record the downstream temperature as before. Try to find a place within reach where the physical conditions most resemble those at the test site.

Water Quality Index

WQI for Temperature Change

Calculations

  1. Subtract the upstream temperature from the temperature downstream and record the result as temperature change (C).
  2. Convert temperature change (C) to water quality index.

     Temperature change:  (C)

    Water quality index:


More on Water Quality Monitoring


HOME - Calendar - Contacts